Certification/ Class (Standard) N95 (NIOSH-42CFR84) FFP2 (EN 149-2001) KN95
(GB2626-20 06)
P2
(AS/NZ 1716:2012)
Korea
1st Class (KMOEL – 2017-64)
DS
(Japan JMHLW-Notification 214, 2018)
Filter performance – (must be ≥ X% efficient) ≥ 95% ≥ 94% ≥ 95% ≥ 94% ≥ 94% ≥ 95%
Test agent NaCl NaCl and paraffin oil NaCl NaCl NaCl and paraffin oil NaCl
Flow rate 85 L/min 95 L/min 85 L/min 95 L/min 95 L/min 85 L/min
Total inward leakage (TIL)* – tested on human subjects each performing exercises N/A ≤ 8% leakage (arithmetic mean) ≤ 8% leakage (arithmetic mean) ≤ 8% leakage (individual and arithmetic mean) ≤ 8% leakage (arithmetic mean) Inward Leakage measured and included in User Instructions
Inhalation resistance – max pressure drop ≤ 343 Pa ≤ 70 Pa (at 30 L/min)≤ 240 Pa (at 95 L/min)≤ 500 Pa (clogging) ≤ 350 Pa ≤ 70 Pa (at 30 L/min)≤ 240 Pa (at 95 L/min) ≤ 70 Pa (at 30 L/min)≤ 240 Pa (at 95 L/min) ≤ 70 Pa (w/valve)≤ 50 Pa (no valve)
Flow rate 85 L/min Varied – see above 85 L/min Varied – see above Varied – see above 40 L/min
Exhalation resistance – max pressure drop ≤ 245 Pa ≤ 300 Pa ≤ 250 Pa ≤ 120 Pa ≤ 300 Pa ≤ 70 Pa (w/valve)≤ 50 Pa (no valve)
Flow rate 85 L/min 160 L/min 85 L/min 85 L/min 160 L/min 40 L/min
Exhalation valve leakage requirement Leak rate ≤ 30 mL/min N/A Depressurizatio n to 0 Pa ≥ 20 sec Leak rate ≤ 30 mL/min visual inspection after 300 L /min for 30 sec Depressurizatio n to 0 Pa ≥ 15 sec
Force applied -245 Pa N/A -1180 Pa -250 Pa N/A -1,470 Pa
CO2 clearance requirement N/A ≤ 1% ≤ 1% ≤ 1% ≤ 1% ≤ 1%
*Japan JMHLW-Notification 214 requires an Inward Leakage test rather than a TIL test